Get the world's most complete ballistics calculator -- a rugged Kestrel Weather Meter with the "science of accuracy" built-in! Get accurate measurement of wind and air density to deliver elevation and windage solutions for unprecedented accuracy on extended long-range shots.
QUICK LOOK:
- Accurate Environmentals – Measures wind speed, wind direction, air pressure, and temperature
- G1/G7 Ballistics Solver – Applied Ballistics library of lab tested bullet data and Applied Ballistics Ultralite™ ballistics engine. Expect extreme accuracy out to the max range of 875yds
- Customizable Shooting Solutions - Ballistics data specific to your rifle, bullet, and scope
- Single Target Display - Easily view the elevation and windage solutions for your shot
- Wind Capture - Intuitive Wind Capture feature instantly measures and adjusts for real-time wind conditions
- User-Friendly – Simple 3 button operation and Easy Mode step-by-step guidance on getting started
- Use With A Vane Mount - The Kestrel Basic Series Vane Mount is the perfect accessory option to help discover wind direction and for a hands-free experience
- Rugged, All-Weather Durability – IP-67 Waterproof, MIL-STD-810 drop-tested, long life battery, and backed by 5-Year Warranty
- Protective Slip-On Cover – Slides over the entire unit for added durability
- Load & Go Convenience – Upload a gun profile for your specific rifle and bullet in the 2700 using the free Kestrel LiNK Ballistics app, then leave your phone behind – the 2700 is a fully functional, stand-alone field tool
- Free Kestrel LiNK Ballistics App – View solutions remotely and easily build, store, and transfer gun and bullet data to and from unit and view solutions remotely using the Kestrel LiNK Ballistics App
FEATURES:
- 3-Button Control
- Digital Compass
- Drop-Tested to MIL-STD-810G
- Hard Slip-On Protective Cover
- High Contrast, Sunlight Readable Monochrome LCD Display
- LiNK Wireless Communication to Mobile Devices (Bluetooth low energy)*
- Pressure Sensor
- Temperature Sensor (Patented External Isolated)
- Waterproof to IP67 (3'/1M for 30 minutes)
- G1/G7 Drag Models
- Muzzle Velocity Calibration
- Supports Mil, MOA, Clicks
USES:
- Hunting
- Law Enforcement
- Military Weather & Environmental Monitoring
- Shooting
OVERVIEW:
Combining onsite wind and weather measurements with an extremely accurate ballistics calculator, the all new Kestrel 2700 keeps the options simple while amping up the performance capabilities to take long-range shots with confidence. Much more than a wind and weather meter - this unit is a powerful and effective tool for making first-round hits.
Inside the Kestrel 2700 Ballistics Weather Meter is a powerful G1/G7 ballistics solver by Applied Ballistics to ensure that you hit your target on the first shot, out to 875 yards. The single target display allows you to easily view the elevation and windage solutions for your shot. Whether out on a hunt or just at the range, the Kestrel 2700 Ballistics Weather Meter is the rugged handheld solution to ensure your shot finds its target.
INCLUDES:
- Battery - 1 x CR2032
- Certificate Of Conformity (Spec Sheet)
- Instructions
- Lanyard
- Protective Cover - Hard Slip-on
MODEL COMPARISON:
Kestrel 2700 Platform | Kestrel 5700 Platform | Kestrel 5700 Elite Platform | ||||
Kestrel 2700 | Kestrel 5700 | Ruger Kestrel 5700 | Hornady Kestrel 5700 | Kestrel 5700 Elite | Kestrel 5700X Elite | |
LiNK Enabled | X | X | X | X | X | X |
G1/G7 Drag Models in Mil, TMOA, SMOA, in, cm, Clicks | X | X | X | X | X | X |
Corrects for Wind, Temp, & Altitude Changes | X | X | X | X | X | X |
Easy Mode | X | X | X | X | X | |
MV Calibration Guide | X | X | X | X | X | |
Gun Profile Storage | 1 Gun | 3 Guns | 3 Guns | 3 Guns | 30 Guns | 30 Guns |
Targets | 1 Target | 1 Target | 1 Target | 1 Target | 30 Stages with 10 targets each | 30 Stages with 10 targets each |
Aerodynamic Cross Wind Jump | X | X | X | X | X | |
Coriolis | X | X | X | X | X | |
Spin Drift | X | X | X | X | X | |
Muzzle Velocity - Temperature Correction | X | X | X | X | X | |
Moving Target Lead Calculator | X | X | X | X | X | |
Target Range Estimator | X | X | X | X | X | |
Target Speed Estimator | X | X | X | X | X | |
Ruger Rifles & Match Grade Ammo Library | X | |||||
Hornady 4DOF Custom Bullet File | X | |||||
Axial Form Factor Calibration Guide | X | |||||
Zero Angle | X | |||||
Range Card | X | X | ||||
Target Card | X | X | ||||
Applied Ballistics Custom Curves | X | X | ||||
Subsonic Range Truing (Drop Scale Factor) | X | X | ||||
Zero Offset | X | X | ||||
Faster Processor Speed for ELR | X | |||||
Adjustable Bluetooth Strength Settings | X | |||||
Max Range | 875 Yards | 4000 Yards | 4000 Yards | 3828 Yards | 5500 Yards | 5500 Yards |
SPECIFICATIONS:
SENSORS | ||||
SENSORS | ACCURACY | RESOLUTION | SPECIFICATION RANGE | NOTES |
Wind Speed | Air Speed | Larger of 3% of reading, least significant digit or 20 ft/min Speed | 0.1 m/s 1 ft/min 0.1 km/h 0.1 mph 0.1 knots 1 B* 0.1 F/S* |
0.6 to 40.0 m/s 118 to 7,874 ft/min 2.2 to 144.0 km/h 1.3 to 89.5 mph 1.2 to 77.8 knots 0 to 12 B* 2-131.2* |
1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s |79 ft min|1.5 km/h |.9 mph |.8 kt after impeller startup. Off-axis accuracy -1% @ 5º off axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH|7 m/s. Replacement impeller (NK PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. Measuring wind speeds above 60 m/s / 134.2 mph can damage the impeller |
Ambient Temperature | 0.9 °F 0.5 °C |
0.1 °F 0.1 °C |
-20.0 to 158.0 °F -29.0 to 70.0 °C |
Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits. |
Relative Humidity | 2%RH | 0.1 %RH | 10 to 90% 25°C noncondensing | To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year. |
Pressure | 1.5 hPa|mbar 0.044 inHg 0.022 PSI |
0.1 hPa|mbar 0.01 inHg 0.01 PSI |
25°C/77°F 700-1100 hPa|mbar 20.67-32.48 inHg 10.15-15.95 PSI |
Monolithic silicon piezo-resistive pressure sensor with second-order temperature correction. Between 1100–1600 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1600 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product. |
Compass | 5° | 1° 1/16th Cardinal Scale |
0 to 360° | 2-axis solid-state magneto-resistive sensor mounted perpendicular to unit plane. Accuracy of sensor dependent upon unit’s vertical position. Self-calibration routine eliminates magnetic error from batteries or unit and must be run after every full power- down (battery removal or change). Readout indicates direction to which the back of the unit is pointed when held in a vertical orientation. Declination/variation adjustable for True North readout. |
CALCULATED MEASUREMENTS | |||
MEASUREMENT | ACCURACY (+/-) | RESOLUTION | SENSORS EMPLOYED |
Air Density | 0.0002 lb/ft3 0.0033 kg/m |
0.001 lbs/ft3 0.001 kg/m3 |
Temperature, Relative Humidity Pressure |
Air Flow | 6.71% | 1 cfm 1 m3/hr 1 m3/m 0.1m3/s 1 L/s |
Air Speed, User Input (Duct Shape & Size) |
Altitude | typical: 23.6 ft/7.2 m from 750 to 1100 mBar max: 48.2 ft/14.7 m from 300 to 750 mBar |
1 ft 1 m | Pressure, User Input (Reference Pressure) |
Barometric Pressure | 0.07 inHg 2.4 hPa|mbar 0.03 PSI |
0.01 inHg 0.1 hPa|mbar 0.01 PSI |
Pressure, User Input (Reference Altitude) |
Crosswind & Headwind/Tailwind | 7.1% | 1 mph 1 ft/min 0.1 km/h 0.1 m/s 0.1 knots |
Wind Speed, Compass |
Delta T | 3.2 °F 1.8 °C |
0.1 °F 0.1 °C | Temperature, Relative Humidity Pressure |
Density Altitude | 226 ft 69 m |
1 ft 1 m | Temperature, Relative Humidity Pressure |
Dew Point | 3.4 °F 1.9 °C 15- 95% RH. Refer to Range for Temperature Sensor |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
Evaporation Rate | 0.01 lb/ft2/hr 0.06 kg/m2/hr |
0.01 b/ft2/hr 0.01 kg/m2/hr |
Wind Speed, Temperature Relative Humidity Pressure, User Input (Concrete Temperature) |
Heat Index | 7.1°F 4.0°C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
Moisture Content | Humidity Ratio (“Grains”) | 4.9gpp .7g/kg |
0.1 gpp 0.01 g/kg |
Temperature, Relative Humidity Pressure |
Probability of Ignition (PIG) | PIG Accuracy dependent on proximity of inputs to reference table steps. | 10% | Temperature, Relative Humidity |
THI (NRC) | 1.5 °F 0.8 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
THI (Yousef) | 2.3 °F 1.3 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
Relative Air Density | .0.3% | 0.1% | Temperature, Relative Humidity Pressure |
Wet Bulb Temperature - Psychrometric | 3.2 °F 1.8 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity Pressure |
Wet Bulb Temperature - Naturally Aspirated (NWB TEMP) | 1.4 °F 0.8 °C |
0.1 °F 0.1 °C |
Wind Speed, Temperature Globe Temperature, Relative Humidity, Pressure |
Wind Chill | 1.6 °F 0.9 °C |
0.1 °F 0.1 °C |
Wind Speed, Temperature |
ADDITIONAL PRODUCT INFO | |
Display & Backlight | Multifunction, multidigit monochrome dot-matrix display. Choice of white or red LED backlight. |
Response Time & Display Update | Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity. WBGT requires about 8 minutes to reach 95% accuracy and about 15 minutes to reach 99% accuracy after exposure to large environmental changes. |
Data Storage & Graphical display Min/Max/Avg History | Logged history stored and displayed for every measured value. Manual and auto data storage. Min/Max/Avg history may be reset independently. Auto-store interval settable from 2 seconds to 12 hours*, overwrite on or off. Logs even when display off except for 2 and 5 second intervals. Kestrel 5 series units hold over 10,000 data points. |
data Upload & Bluetooth Data Connect Option | Wireless range up to 100ft. Connection requires optional USB data transfer cable or Kestrel Link Dongle or Kestrel LiNK app. Employs Kestrel Link protocol for data transmission with Link supported devices. (Kestrel LiNK for iOS/Android, Kestrel Link for PC/MAC). |
Clock/Calendar | Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment. |
Auto Shutdown | User-selectable – Off, 15-60 minutes with no key presses. |
Languages | English, French, German, Spanish. |
Certifications | CE certified, RoHS, FCC, IC tested and WEEE compliant. Individually tested to NIST-traceable standards. |
Origin | Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B. |
Battery Life | AA Lithium included. Up to 400 hours of use, reduced by backlight, alert light and buzzer, or Bluetooth radio transmission use. |
Shock Resistance | MIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller. |
Sealing | Waterproof (IP67 and NEMA-6) |
Display & Battery Operational Temperature Limits | 14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading. |
Storage Temperature | -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C. |
Size & Weight | 5.0 x 1.9 x 1.1 in | 12.7 x 4.5 x 2.8 cm, 4.3 oz | 121 g. (Lithium battery included) |